Banner page

Single Mode G652D G657A1 GYTS 12 Core Pipeline Outdoor Fiber Optic Cable

Short Description:

+ Use for outdoor such as pipeline, under ground, duct or direct burial

+ Fiber count: 2 fibers, 4 fibers, 6 fibers,  8 fibers, 12 fibers, 24 fibers

+ Fiber type:

SM: G652D, SM G657A1, SM G657A2, G655

MM: OM1, OM2,  OM3,  OM4,  OM5

+ Cable out-sheath: PE, black

+ Cable diameter: 7.0mm ( 6.5mm, 8.0mm optional)

+ Cable printing and labelling: accept.


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Product Detail

    Product Tags

    GYTS Cable Technical Data

    Item

    Parameters

    Loose tube

    Material

    PBT

    Color

    Full color spectrum

    Filler

    Material

    PE

    Color

    Black

    CSM

    Material

    Phosphating steel wire

    Armoured

    Material

    Plastic coated aluminum strip

    Outer jacket

    Material

    MDPE

    Color

    Black

    Min. bending radius

    Static

    10 times cable diameter

    Dynamic

    20 times cable diameter

    Repeating bending

    Load150N;number of cycles:30  No obvious addition attenuation, no fiber break and no cable damage.

    Tensile performance

    Short term

    1500N

    Crush

    Short term

    1000N/100mm

    Torsion

    Load150N; number of cycles:10; twist angle:±180° No obvious addition attenuation, no fiber break and no cable damage.

    Impact

    Impact energy450g×1m; radius of hammer head:12.5mm; number of impact: 5  No obvious addition attenuation, no fiber break and no cable damage.

    Fiber characteristic:

    Fiber style Unit SM

    G652D

    SM

    G657A

    MM

    50/125

    MM

    62.5/125

    MM

    OM3-300

    MM

    OM4-550

    Condition nm 1310/1550 1310/625 850/1300 850/1300 850/1300 850/1300
    Attenuation dB/km ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 ≤3.5/2.2
    Dispersion 1550nm Ps/(nm*km) ≤18 ≤18 ---- ----

    ----

    ----

      1625nm Ps/(nm*km) ≤22 ≤22 ---- ----

    ----

    ----

    Bandwidth 850nm MHZ.KM ----   ≥400 ≥160    
      1300nm MHZ.KM ----   ≥800 ≥500
    Zero dispersion wavelength nm ≥1302

    ≤1322

    ≥1302

    ≤1322

    ---- ---- ≥ 1295,

    ≤1320

    ≥ 1295,

    ≤1340

    Zero dispersion slope nm ≤0.091 ≤0.090 ---- ---- ---- ----
    PMD Maximum Individual Fiber ≤0.2 ≤0.2 ---- ---- ≤0.11  
    PMD Design Link Value Ps(nm2*km) ≤0.08 ≤0.1 ---- ---- ---- ----
    Fibre cutoff wavelength λc nm ≥1180

    ≤1330

    ≥1180

    ≤1330

    ---- ---- ---- ----
    Cable cutoff

    wavelength λcc

    nm ≤1260 ≤1260 ---- ---- ---- ----
    MFD 1310nm um 9.2±0.4 9.0±0.4 ---- ---- ---- ----
      1550nm um 10.4±0.8 10.1±0.5 ---- ---- ---- ----
    Numerical

    Aperture (NA)

    ---- ---- 0.200± 0.015 0.275±

    0.015

    0.200±

    0.015

    0.200±

    0.015

    Step (mean of bidirectional

    measurement)

    dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Irregularities over fiber length and point dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Difference backscatter

    coefficient

    dB/km ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08 ≤0.08
    Attenuation uniformity dB/km ≤0.01 ≤0.01  
    Core diameter um  9 9 50±1.0 62.5±2.5 50±1.0 50±1.0
    Cladding diameter um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
    Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
    Coating diameter um 242±7 242±7 242±7 242±7 242±7 242±7
    Coating/chaffinch

    concentrically error

    um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
    Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
    Core/cladding concentricity error um ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5 ≤1.5
    Curl(radius) um ≤4 ≤4 ---- ---- ---- ----

    Fiber color:

    1 2 3 4 5 6
    Blue Orange Green Brown Grey White
    7 8 9 10 11 12
    Red Black Yellow Violet Pink Aqua
    Fibre-Optic-Cable-Colours -code

    GYTS Cable Description

    + GYTS (metal strengthening member, loose tube stranded and filled, steel-polyethylene bonded sheathed outdoor optical fiber cable for communication).

    + The structure of the optical cable is to sheath single-mode or multi-mode optical fiber into the inner filling made of high modulus plastic Waterproof compound in loose tube.

    + The center of the cable core is a metal reinforced core. For some fiber optic cables, the metal reinforced core is also extruded with a layer of polyethylene (PE).

    + The loose tube (and filling rope) is twisted around the central reinforcing core to form a compact and circular cable core, and the gaps in the cable core are filled with water blocking compounds.

    + The steel-plastic composite tape is longitudinally wrapped and then extruded with a polyethylene sheath.

    GYTS Cable Construction:

    KCO GYTS Cable

    GYTS Cable Characteristics:

    + Good mechanical and temperature performance

    + High strength loose tube that is hydrolysis resistant

    + Special tube filling compound ensure a critical protection of fiber

    + Specially designed compact structure is good at preventing loose tubes from shrinking

    + PE sheath protects cable from ultraviolet radiation

    + The following measures are taken to ensure the cable watertight:

    + Steel wire used as the central strength member

    + Loose tube filling compound

    + 100% cable core filling

    + 100% tested before shipment. 

    + Cable reel length: 1km, 2km, 3km, 5km 

    GYTA Cable Application:

    + Adopted to Outdoor distribution.

    + Suitable for pipeline laying, direct burial, under ground method.

    + Long distance and local area network communication.

    Packing:

    KCO FIber - Outdoor Cable Packing

  • Previous:
  • Next:

  • Write your message here and send it to us