KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)

Short Description:

• Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV) is used in fiber optical pigtails and fiber optical patch cords.
• It used as interconnect lines of equipments,and used in optical connections in optical  communication rooms and optical distribution frames.
• It is large used in indoor cabling, especially used as distribution cable.
• Good mechanical and environmental characteristics.
• Flame retardant characteristics meet the requirements of relevant standards.
• The mechanical characteristics of jacked meet the requirements of relevant standards.
• The fanout indoor fiber optic cable is soft, flexible, easy to lay and splice and with big capacity data transmission.
• Meet various requirements of market and clients.


Product Detail

Product Tags

Technical Parameters:

Fanout Indoor Fiber Optical Cable (GJFJV) Cable diameter Weight
2 cores 4.5mm 22.00kg/km
4 cores 4.5mm 22.00kg/km
6 cores 4.5mm 23.00kg/km
8 cores 5.5mm 27.00kg/km
10 cores 5.5mm 30.00kg/km
12 cores 6.0mm 35.00kg/km
Storage temperature (℃) -20+60
Min Bending Radius(mm) Long term 10D
Min Bending Radius(mm) Short term 20D
Min allowable Tensile Strength(N) Long term 200
Min allowable Tensile Strength(N) Short term 600
Crush Load (N/100mm) Long term 200
Crush Load (N/100mm) short term 1000

Fiber characteristic:

Fiber style Unit SMG652 SMG652D SMG657A MM50/125 MM62.5/125 MMOM3-300
condition nm 1310/1550 1310/1550 1310/625 850/1300 850/1300 850/1300
attenuation dB/km ≤0.36/0.23 ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0
Dispersion 1550nm Ps/(nm*km) ---- ≤18 ≤18 ---- ----

----

  1625nm Ps/(nm*km) ---- ≤22 ≤22 ---- ----

----

Bandwidth 850nm MHZ.KM ---- ----   ≥400 ≥160  
  1300nm MHZ.KM ---- ----   ≥800 ≥500  
Zero dispersion wavelength nm ≥1302≤1322 ≥1302≤1322 ≥1302≤1322 ---- ---- ≥ 1295,≤1320
Zero dispersion slope nm ≤0.092 ≤0.091 ≤0.090 ---- ---- ----
PMD Maximum Individual Fiber   ≤0.2 ≤0.2 ≤0.2 ---- ---- ≤0.11
PMD Design Link Value Ps(nm2*km) ≤0.12 ≤0.08 ≤0.1 ---- ---- ----
Fibre cutoff wavelength λc nm ≥ 1180≤1330 ≥1180≤1330 ≥1180≤1330 ---- ---- ----
Cable cutoffwavelength λcc nm ≤1260 ≤1260 ≤1260 ---- ---- ----
MFD 1310nm um 9.2±0.4 9.2±0.4 9.0±0.4 ---- ---- ----
  1550nm um 10.4±0.8 10.4±0.8 10.1±0.5 ---- ---- ----
NumericalAperture(NA)   ---- ---- ---- 0.200± 0.015 0.275±0.015 0.200±0.015
Step(mean of bidirectionalmeasurement) dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Irregularities over fiberlength and point dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Discontinuity  
Difference backscattercoefficient dB/km ≤0.05 ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08
Attenuation uniformity dB/km ≤0.01 ≤0.01 ≤0.01      
Core diameter um  9  9 9 50±1.0 62.5±2.5 50±1.0
Cladding diameter um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
Coating diameter um 242±7 242±7 242±7 242±7 242±7 242±7
Coating/chaffinchconcentrically error um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
Core/cladding concentricity error um ≤0.6 ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5
Curl(radius) um ≤4 ≤4 ≤4 ---- ---- ----

Cable Constructions:

图片 2

Cable Cut-Out:

图片 4

 Multimode OM3 8 cores Cable

图片 3

Single mode 4 cores Cable

图片 5

 Multimode 50/125 24 cores Cable 

Descriptions:

• The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable use 2~48 core (or more) use 900μm or 600μm tight buffer fiber as optical sub cable. Normally it cover use PVC or LSZH, also use PE or Nilon.

• The tight buffer fiber wrapped with a layer of aramid yarn as strength member, then completed with a layer of PVC or LSZH material as out jacket.

• The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable out jacket color: 

Single mode: Yellow,

Multimode OM1 / OM2: Orange,

Multimode OM3 / OM4: Aqua,

Multimode OM4: Violet,

Mutimode OM5: Lime.

Other color is optional.

Application:

+ Used in pigtails and patch cords.

+ Used as interconnect lines of equipments, and used in optical connections in optical  communication rooms, data center and optical distribution frames.

+ Used in indoor cabling, especially used as distribution cable.

distribution cable application -1

Characteristics:

• Good mechanical and environmental characteristics.

• Flame retardant characteristics meet the requirements of relevant standards.

• The mechanical characteristics of jacked meet the requirements of relevant standards.

• Soft,flexible,easy to lay and splice,and with big capacity data transmission.

• Meet various requirements of market and clients.

Application: used for indoor cable fan-out multi fibers pigtail/ patch cord

+ Used in pigtails and patch cords.

+ Used as interconnect lines of equipments,and used in optical connections in optical
communication rooms and optical distribution frames.

+ Used in indoor cabling,especially used as distribution cable.

distribution cable application -1

Packing:

distribution cable packing -2
distribution cable packing-1

  • Previous:
  • Next:

  • Write your message here and send it to us