KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

Light Armored Outdoor Fiber Optic Cable GYTA For Duct Pipe Line Underground Direct Burial

Short Description:

+ Cable type: GYTA

+ Application: aerial, pipe line, under ground, direct burial, duct 

+ Fiber count: 2 to 96 fibers 

+ Fiber type:

SM: G652D, SM G657A1, SM G657A2, G655

MM: OM1, OM2,  OM3,  OM4,  OM5

+ Cable out-sheath: PE, black

+ Cable diameter: 8.5mm

+ Cable printing and labelling: accept.


  • Unit Price: US $0.02 - 99.99 / Piece
  • MOQ: 10 Piece/Pieces
  • Supply Ability: 100000pcs/Month
  • Origin: Guangdong, China
  • Seaport/airport : Shenzhen
  • Product Detail

    Product Tags

    Light Armored Outdoor Fiber Optic Cable GYTA Description

    - Light Armored Outdoor Fiber Optic Cable GYTA is an outdoor communication fiber optic cable featuring a stranded loose tube design and aluminum-polyethylene laminate (APL) armor.

    - It is highly optimized for duct/conduit and aerial lashed installations where superior moisture exclusion and mechanical reliability are essential. 

    Light Armored Outdoor Fiber Optic Cable GYTA Main Structure

    1. Central Strength Member (CSM):

    A phosphatized steel wire sits at the center of the core to absorb tensile load. For higher fiber counts, it may be upjacketed with a polyethylene (PE) layer to match core geometry.

    2. Optical Fibers:

    Standard 250µm bare fibers, typically conforming to G652D single-mode specifications (Single mode G657, G655 and Multimode fiber are also used).

    3. Gel-Filled Loose Tubes:

    The fibers are contained in high-modulus PBT (polybutylene terephthalate) loose tubes filled with a thixotropic, water-resistant gel to act as a physical buffer and moisture block.

    4. SZ Core Stranding:

    The loose tubes (and any necessary solid plastic fillers) are helically stranded around the CSM using an SZ pattern. The interstitial gaps within the stranded core are packed with a water-blocking filling compound.

    5. Inner Moisture Armor (APL):

    An Aluminum Polyethylene Laminate (APL) tape is applied longitudinally over the stranded core. This acts as a radial moisture barrier and provides crush resistance.

    6. Outer Jacket:

    A dense, black, UV-resistant Polyethylene (PE) outer sheath is extruded over the APL tape to protect the entire assembly from abrasion, environmental weathering, and solar degradation.

    GYTA Cable Technical Data

    Parameter Specifications  Standard
    Fiber Count Range 2 to 144 cores (Up to 288 cores)              IEC 60794 / YD/T 901      
    Nominal Outer Diameter         8.5 mm to 15.5 mm —
    Nominal Cable Weight 75 kg/km to 270 kg/km —
    Tensile Resistance Short-Term: 1500 N 

    Long-Term: 600 N

    IEC 60794-1-2-E1
    Crush Resistance Short-Term: 1000 N/100mm     IEC 60794-1-2-E3
    Minimum Bend Radius Static: 10 × OD

    Dynamic: 20 × OD

    IEC 60794-1-2-E11
    Attenuation (G652D fiber) ≤ 0.36 dB/km @ 1310nm

    ≤ 0.22 dB/km @ 1550nm

    ITU-T G.652.D
    Temperature Profile Operation: -40°C to +70°C 

    Installation: -10°C to +60°C

    —

    Fiber characteristic:

    Fiber style Unit SM

    G652D

    SM

    G657A

    MM

    50/125

    MM

    62.5/125

    MM

    OM3-300

    MM

    OM4-550

    Condition nm 1310/1550 1310/625 850/1300 850/1300 850/1300 850/1300
    Attenuation dB/km ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0 ≤3.5/2.2
    Dispersion 1550nm Ps/(nm*km) ≤18 ≤18 ---- ----

    ----

    ----

      1625nm Ps/(nm*km) ≤22 ≤22 ---- ----

    ----

    ----

    Bandwidth 850nm MHZ.KM ----   ≥400 ≥160    
      1300nm MHZ.KM ----   ≥800 ≥500
    Zero dispersion wavelength nm ≥1302

    ≤1322

    ≥1302

    ≤1322

    ---- ---- ≥ 1295,

    ≤1320

    ≥ 1295,

    ≤1340

    Zero dispersion slope nm ≤0.091 ≤0.090 ---- ---- ---- ----
    PMD Maximum Individual Fiber ≤0.2 ≤0.2 ---- ---- ≤0.11  
    PMD Design Link Value Ps(nm2*km) ≤0.08 ≤0.1 ---- ---- ---- ----
    Fibre cutoff wavelength λc nm ≥1180

    ≤1330

    ≥1180

    ≤1330

    ---- ---- ---- ----
    Cable cutoff

    wavelength λcc

    nm ≤1260 ≤1260 ---- ---- ---- ----
    MFD 1310nm um 9.2±0.4 9.0±0.4 ---- ---- ---- ----
      1550nm um 10.4±0.8 10.1±0.5 ---- ---- ---- ----
    Numerical

    Aperture (NA)

    ---- ---- 0.200± 0.015 0.275±

    0.015

    0.200±

    0.015

    0.200±

    0.015

    Step (mean of bidirectional

    measurement)

    dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Irregularities over fiber length and point dB ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10 ≤0.10
    Difference backscatter

    coefficient

    dB/km ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08 ≤0.08
    Attenuation uniformity dB/km ≤0.01 ≤0.01  
    Core diameter um  9 9 50±1.0 62.5±2.5 50±1.0 50±1.0
    Cladding diameter um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
    Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
    Coating diameter um 242±7 242±7 242±7 242±7 242±7 242±7
    Coating/chaffinch

    concentrically error

    um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
    Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
    Core/cladding concentricity error um ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5 ≤1.5
    Curl(radius) um ≤4 ≤4 ---- ---- ---- ----

    Fiber color:

    1 2 3 4 5 6
    Blue Orange Green Brown Grey White
    7 8 9 10 11 12
    Red Black Yellow Violet Pink Aqua
    Fibre-Optic-Cable-Colours -code

    GYTA Cable:

    GYFTA cable

    GYTA Cable Application:

    + Adopted to Outdoor distribution.

    + Suitable for pipeline laying, direct burial, under ground method.

    + Long distance and local area network communication.

    Packing:

    KCO FIber - Outdoor Cable Packing

  • Previous:
  • Next:

  • Write your message here and send it to us