Banner page

Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)

Short Description:

Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV) is used in fiber optical pigtails and fiber optical patch cords.
It used as interconnect lines of equipments,and used in optical connections in optical  communication rooms and optical distribution frames.
It is large used in indoor cabling, especially used as distribution cable.
Good mechanical and environmental characteristics.
 Flame retardant characteristics meet the requirements of relevant standards.
 The mechanical characteristics of jacked meet the requirements of relevant standards.
The fanout indoor fiber optic cable is soft, flexible, easy to lay and splice and with big capacity data transmission.
• Meet various requirements of market and clients.


Product Detail

Product Tags

Technical Parameters:

Fanout Indoor Fiber Optical Cable (GJFJV) Cable diameter Weight
2 cores 4.5mm 22.00kg/km
4 cores 4.5mm 22.00kg/km
6 cores 4.5mm 23.00kg/km
8 cores 5.5mm 27.00kg/km
10 cores 5.5mm 30.00kg/km
12 cores 6.0mm 35.00kg/km
Storage temperature (℃) -20+60
Min Bending Radius(mm) Long term 10D
Min Bending Radius(mm) Short term 20D
Min allowable Tensile Strength(N) Long term 200
Min allowable Tensile Strength(N) Short term 600
Crush Load (N/100mm) Long term 200
Crush Load (N/100mm) short term 1000

Fiber characteristic:

Fiber style Unit SMG652 SMG652D SMG657A MM50/125 MM62.5/125 MMOM3-300
condition nm 1310/1550 1310/1550 1310/625 850/1300 850/1300 850/1300
attenuation dB/km ≤0.36/0.23 ≤0.34/0.22 ≤.035/0.21 ≤3.0/1.0 ≤3.0/1.0 ≤3.0/1.0
Dispersion 1550nm Ps/(nm*km) ---- ≤18 ≤18 ---- ----

----

  1625nm Ps/(nm*km) ---- ≤22 ≤22 ---- ----

----

Bandwidth 850nm MHZ.KM ---- ----   ≥400 ≥160  
  1300nm MHZ.KM ---- ----   ≥800 ≥500  
Zero dispersion wavelength nm ≥1302≤1322 ≥1302≤1322 ≥1302≤1322 ---- ---- ≥ 1295,≤1320
Zero dispersion slope nm ≤0.092 ≤0.091 ≤0.090 ---- ---- ----
PMD Maximum Individual Fiber   ≤0.2 ≤0.2 ≤0.2 ---- ---- ≤0.11
PMD Design Link Value Ps(nm2*km) ≤0.12 ≤0.08 ≤0.1 ---- ---- ----
Fibre cutoff wavelength λc nm ≥ 1180≤1330 1180≤1330 ≥1180≤1330 ---- ---- ----
Cable cutoffwavelength λcc nm ≤1260 ≤1260 ≤1260 ---- ---- ----
MFD 1310nm um 9.2±0.4 9.2±0.4 9.0±0.4 ---- ---- ----
  1550nm um 10.4±0.8 10.4±0.8 10.1±0.5 ---- ---- ----
NumericalAperture(NA)   ---- ---- ---- 0.200± 0.015 0.275±0.015 0.200±0.015
Step(mean of bidirectionalmeasurement) dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Irregularities over fiberlength and point dB ≤0.05 ≤0.05 ≤0.05 ≤0.10 ≤0.10 ≤0.10
Discontinuity  
Difference backscattercoefficient dB/km ≤0.05 ≤0.03 ≤0.03 ≤0.08 ≤0.10 ≤0.08
Attenuation uniformity dB/km ≤0.01 ≤0.01 ≤0.01      
Core diameter um  9  9 9 50±1.0 62.5±2.5 50±1.0
Cladding diameter um 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1 125.0±0.1
Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0 ≤1.0
Coating diameter um 242±7 242±7 242±7 242±7 242±7 242±7
Coating/chaffinchconcentrically error um ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0 ≤12.0
Coating non circularity % ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0 ≤6.0
Core/cladding concentricity error um ≤0.6 ≤0.6 ≤0.6 ≤1.5 ≤1.5 ≤1.5
Curl(radius) um ≤4 ≤4 ≤4 ---- ---- ----

Cable Constructions:

图片 2

Cable Cut-Out:

图片 4

 Multimode OM3 8 cores Cable

图片 3

Single mode 4 cores Cable

图片 5

 Multimode 50/125 24 cores Cable 

Descriptions:

The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable use 2~48 core (or more) use 900μm or 600μm tight buffer fiber as optical sub cable. Normally it cover use PVC or LSZH, also use PE or Nilon.

• The tight buffer fiber wrapped with a layer of aramid yarn as strength member, then completed with a layer of PVC or LSZH material as out jacket.

The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable out jacket color: 

Single mode: Yellow,

Multimode OM1 / OM2: Orange,

Multimode OM3 / OM4: Aqua,

Multimode OM4: Violet,

Mutimode OM5: Lime.

Other color is optional.

Application:

+ Used in pigtails and patch cords.

+ Used as interconnect lines of equipments, and used in optical connections in optical  communication rooms, data center and optical distribution frames.

+ Used in indoor cabling, especially used as distribution cable.

distribution cable application -1

Characteristics:

Good mechanical and environmental characteristics.

• Flame retardant characteristics meet the requirements of relevant standards.

 The mechanical characteristics of jacked meet the requirements of relevant standards.

• Soft,flexible,easy to lay and splice,and with big capacity data transmission.

• Meet various requirements of market and clients.

Application: used for indoor cable fan-out multi fibers pigtail/ patch cord

+ Used in pigtails and patch cords.

+ Used as interconnect lines of equipments,and used in optical connections in optical
communication rooms and optical distribution frames.

+ Used in indoor cabling,especially used as distribution cable.

distribution cable application -1

Packing:

distribution cable packing -2
distribution cable packing-1

  • Previous:
  • Next:

  • Write your message here and send it to us