Distribution Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)
Technical Parameters:
| Fanout Indoor Fiber Optical Cable (GJFJV) | Cable diameter | Weight | |
| 2 cores | 4.5mm | 22.00kg/km | |
| 4 cores | 4.5mm | 22.00kg/km | |
| 6 cores | 4.5mm | 23.00kg/km | |
| 8 cores | 5.5mm | 27.00kg/km | |
| 10 cores | 5.5mm | 30.00kg/km | |
| 12 cores | 6.0mm | 35.00kg/km | |
| Storage temperature (℃) | -20+60 | ||
| Min Bending Radius(mm) | Long term | 10D | |
| Min Bending Radius(mm) | Short term | 20D | |
| Min allowable Tensile Strength(N) | Long term | 200 | |
| Min allowable Tensile Strength(N) | Short term | 600 | |
| Crush Load (N/100mm) | Long term | 200 | |
| Crush Load (N/100mm) | short term | 1000 | |
Fiber characteristic:
| Fiber style | Unit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| condition | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| attenuation | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Dispersion | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- |
---- |
|
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- |
---- |
||
| Bandwidth | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Zero dispersion wavelength | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Zero dispersion slope | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| PMD Maximum Individual Fiber | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD Design Link Value | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Fibre cutoff wavelength λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Cable cutoffwavelength λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumericalAperture(NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Step(mean of bidirectionalmeasurement) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Irregularities over fiberlength and point | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Discontinuity | |||||||||
| Difference backscattercoefficient | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Attenuation uniformity | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Core diameter | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Cladding diameter | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Coating diameter | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Coating/chaffinchconcentrically error | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Core/cladding concentricity error | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Curl(radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Cable Constructions:
Cable Cut-Out:
Multimode OM3 8 cores Cable
Single mode 4 cores Cable
Multimode 50/125 24 cores Cable
Descriptions:
• The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable use 2~48 core (or more) use 900μm or 600μm tight buffer fiber as optical sub cable. Normally it cover use PVC or LSZH, also use PE or Nilon.
• The tight buffer fiber wrapped with a layer of aramid yarn as strength member, then completed with a layer of PVC or LSZH material as out jacket.
• The Distribution Fanout Tight Buffer Indoor Fiber Optical Cable out jacket color:
Single mode: Yellow,
Multimode OM1 / OM2: Orange,
Multimode OM3 / OM4: Aqua,
Multimode OM4: Violet,
Mutimode OM5: Lime.
Other color is optional.
Application:
+ Used in pigtails and patch cords.
+ Used as interconnect lines of equipments, and used in optical connections in optical communication rooms, data center and optical distribution frames.
+ Used in indoor cabling, especially used as distribution cable.
Characteristics:
• Good mechanical and environmental characteristics.
• Flame retardant characteristics meet the requirements of relevant standards.
• The mechanical characteristics of jacked meet the requirements of relevant standards.
• Soft,flexible,easy to lay and splice,and with big capacity data transmission.
• Meet various requirements of market and clients.
Application: used for indoor cable fan-out multi fibers pigtail/ patch cord
+ Used in pigtails and patch cords.
+ Used as interconnect lines of equipments,and used in optical connections in optical
communication rooms and optical distribution frames.
+ Used in indoor cabling,especially used as distribution cable.
Packing: