Banner page

KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver

Short Description:

- Hot Pluggable QSFP56 Transceiver

- Supports 212,5Gbps aggregate bit rate

- Up to 53.125Gbps data rate per channel

- SFF-8665 compliant QSFP56 port;

- SFF-8636 compliant I2C management

- Compliant with IEEE802.3cd 200GBASE-SR4

- MPO-12 connector receptacle with UPC end-face

- Maximum link length of 100m on OM4 MMF

- Single 3.3V Power Supply

- Low power dissipation (<4.5W)

- Operating case temperature range:0°C to 70 °C

- RoHS compliant


Product Detail

Product Tags

Description

+ The KCO QSFP56 200G SR4 S Fiber Optic Module supports 200GE links and up to two 100GBASE-SR2 breakout links or four 50GBASE-SR lengths of up to 100m over OM4 MMF.

+ The module has four pairs of Multi-Mode Fiber with an MPO-12 UPC connector.

+ It is compliant to the IEEE 802.3bm protocol and 200GAUI-4/CEI-56G-VSR-PAM4 standards.

+ The 200 Gigabit Ethernet signal is carried over four parallel pairs of fibers at a nominal wavelength of 850nm at 50Gbps per fiber. It can also be used as 2x100GE breakout to 100GBASE-SR2modules. FEC is performed on the host platform.

+ The KCO QSFP56 200G SR4 S fiber optic transceivers are high performance, cost effective I/O solutions for LAN, HPC and SAN.

+ The high-speed transceivers meet and exceed 200G Ethernet, InfiniBand HDR and temperature requirements for performance and reliability.

+ The transceivers are compliant with SFF-8636 specifications and provide connectivity between devices using QSFP56 ports.

Application

+ 200GBASE-SR4 Ethernet

+ 200G InfiniBand HDR systems

+ Other optical links

Receiver Optical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

Notes

Bit Rate

BR

-

26.5625± 100 ppm

-

GBd

PAM4

Center Wavelength Range

λc

840

850

860

nm

Damage threshold

DT

5

-

-

dBm

Average receive power, each lane

PIN

-8.4

-

4

dBm

Receive power, each lane (OMAouter)

PINOMA

-

-

3

dBm

Receive Sensitivity

(OMAouter) , each lane

Sen

max-6.5SECQ-7.9

dBm

1,2

Stressed receiver sensitivity (OMAouter), each lane

SenSTR

-

-

-3.4

dBm

1

Receiver reflectance

RF

-

-

-12

dB

Notes:

  1. BER=2.4E-4, PRBS31Q@26.5625Gbd PAM4
  2. Receiver sensitivity is informative and is defined for a transmitter with a value of SECQ.
Receiver Optical Characteristics

Electrical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

Notes

Module Supply Current

Icc

-

-

1364

mA

-

Power Dissipation

PD

-

-

4.5

W

-

Transmitter

Signaling data each lane

-

26.5625± 100 ppm

-

GBd

PAM4

Input Differential Impedance

Zin

90

100

110

Ω

-

Differential Data Input Swing

VIN,P-P,

300

-

900

mVpp

-

Differential termination mismatchal

-

-

-

10

%

-

Single-ended voltage tolerance range

-

-0.4

-

3.3

V

-

DC common mode voltage

-

-350

-

2850

mV

-

Receiver

Signaling rate (each lane)

26.5625 ± 100 ppm

mVpp

PAM4

Output Differential Impedance

Zout

90

100

110

Ω

-

Differential Data Output Swing

VOUT,P-P

300

-

900

mVpp

-

Differential termination mismatch

-

-

-

10

%

-

Data Output Rise Time, Fall Time

Tr/Tf

9.5

-

-

ps

-

DC common mode voltage

-

-350

-

2850

mV

-

Error Bit Rate

BER

-

-

2.4E-4

1

Notes:

  1. PRBS31Q@26.5625Gbd PAM4
Mechanical specifications

  • Previous:
  • Next:

  • Write your message here and send it to us